Meter Units
Meter units are oil proportioning devices for cyclic systems. Each outlet of a lubricating system is controlled by a meter unit. The lubricator in the system dispenses known amounts of oil to the distribution network and meter units deliver this oil in varying amounts to the bearing points.
The first letter of the meter unit identifies the type of threads on the unit. Meter units that begin with the letter “F” denote inch threads, while those that start with the letter “A” signify metric threads.
Standard flow rates range from 00 (medium slow) to 3 (fast). For special situations, 3/0 (slow) and 5 (extra, extra fast) rates are available. Each incremental increase in rate size doubles the oil flow to a point.
Meter units type “F” must be used with all cyclic type lubricators (cannot be used with continuous lubricators). Meter units feed in one direction only. This is indicated by arrow stamped on body.
AJB Meter Units
Inlet: M8x1 male
Outlet: M8x1 (5/32 or 4mm tube) male
AJV PulseFire Meter Units
Inlet: M8x1 male
Outlet: M8x1 (5/32 or 4mm tube) male
ASA Meter Units
Inlet: M8x1 (5/32 or 4mm tube) male
Outlet: 1/8BSPT male
FB Meter Units
Inlet: 1/8NPT male
Outlet: 1/8BSPT male
FJB Meter Units
Inlet: 5/16-24 male
Outlet: 5/16-24 (5/32 or 4mm tube) male
FJC Meter Units
Inlet: 5/16-24 male
Outlet: 5/16-24 (3/32 tube) male
FJD Meter Units
Inlet: 5/16-24 male
Outlet: 1/4-28 (3/32 tube) male
FKA Meter Units
Outlet: 1/8NPT male
FKB Meter Units
Inlet: 1/8NPT male
FKD Meter Units
Outlet: 1/8BSPT male
FRA Meter Units
Inlet: 1/8NPT male
Outlet: 5/16-24 (5/32 or 4mm tube) male
FRC Meter Units
Inlet: 1/8NPT male
Outlet: 5/16-24 (3/32 tube) male
FSA Meter Units
Inlet: 5/16-24 (5/32 or 4mm tube) male
Outlet: 1/8NPT male
FSB Meter Units
Inlet: 5/16-24 (5/32 or 4mm tube) male
Outlet: 1/8BSPT male
FT Meter Units
Inlet: 1/8NPT male
Outlet: 1/8NPT male
FTA Meter Units
Inlet: 5/16-24(x2) (5/32 or 4mm tube) female
Outlet: 1/8NPT male
FTB Meter Units
Inlet: 5/16-24(x3) (5/32 or 4mm tube) female
Outlet: 1/8NPT male
FTC Meter Units
Inlet: 5/16-24(x2) (5/32 or 4mm tube) female
Outlet: 1/8NPT male
FTD Meter Units
Inlet: 5/16-24(x2) (5/32 or 4mm tube) female
Outlet: 1/8NPT male
FTG Meter Units
Inlet: 5/16-24(x3) (5/32 or 4mm tube) female
Outlet: 1/8NPT male
FTH Meter Units
Inlet: 5/16-24(x4) (5/32 or 4mm tube) female
Outlet: 1/8NPT male
FTK Meter Units
Inlet: 5/16-24(x3) (5/32 or 4mm tube) female
Outlet: 1/8NPT male
FTL Meter Units
Inlet: 5/16-24(x4) (5/32 or 4mm tube) female
Outlet: 1/8NPT male
MJ Meter Units
Inlet: 5/16-24 male
Outlet: 5/16-24 (1/8 tube) male
MJC Meter Units
Inlet: 5/16-24 male
Outlet: 5/16-24 (3/32 tube) male
EJB Meter Units
Inlet: 5/16-24 male
Outlet: 5/16-24 (5/32 or 4mm tube) male
ESA Meter Units
Inlet: 5/16-24 (5/32 or 4mm tube) male
Outlet: 1/8NPT male